NOV Type P Liner Spray Inspection: Manifold and Rod Checks

A liner spray inspection sheet should identify the installed cooling arrangement before anyone selects a replacement component or signs off a maintenance action. A generic entry such as “cooling checked” leaves the next shift without enough information to find the component that was inspected.

This guide provides an original documentation checklist for maintenance planners and parts enquiries. It is not a disassembly procedure, a retrofit approval, or a substitute for the manual matched to the pump serial number. Intrusive checks and adjustments require shutdown, energy isolation and verified pressure release under the site's approved procedure; operating observations must use designated safe viewing points with guards in place.

Start with the correct spray arrangement

NOV's Type P booklet, document 25-101131, page 14, describes spray manifolds for 7-P-50 through 12-P-160 models. It separately describes spray through holes in the 14-P-220 piston rod. Both arrangements require daily checks for unobstructed spray. This distinction identifies the inspection location; it does not establish interchangeability or confirm the configuration of a modified pump.

Use the NOV 12-P-160 product page and NOV 14-P-220 product page as catalogue navigation. Confirm the installed assembly against the equipment record and applicable OEM drawing before specifying parts.

Build an inspection record that can be handed over

The following fields are editorial recommendations, not an OEM acceptance standard. Keep one record for each pump and identify each inspected location consistently.

For example, a blank template can prompt “Location ___; arrangement ___; observation ___; document ___; follow-up ___.” Do not prefill it with “normal.” A missing observation should remain open until someone can obtain it safely.

Use separate entries for findings and explanations

Record an interrupted or uneven observed spray as an observation. Do not automatically label it a failed pump, blocked nozzle or damaged piston. Those explanations require further investigation under the applicable procedure. The record should preserve both the original finding and the later confirmed cause, if one is established.

If the physical arrangement differs from the drawing, attach that discrepancy to the work order before requesting a replacement. A catalogue model name by itself cannot resolve a field modification. Avoid converting a photograph into an assumed part number.

Prepare a focused parts enquiry

Include the pump identity, verified assembly drawing reference, existing component marking, location and a clear description of the requested item. State which facts remain unknown. Ask for the proposed part number and documented applicability to the installed assembly before accepting a selection.

Keep the inspection finding separate from the purchasing request: observing poor spray does not determine which component must be replaced. This article provides no universal nozzle setting, coolant mixture, flow threshold or tightening value. Obtain those requirements from the current equipment-specific instructions.

Close the record with evidence

For broader tasks around the pump, use the mud pump daily maintenance checklist. This worksheet addresses spray arrangement and traceable findings; it does not assess liner bore wear or authorize the pump to return to service.

Source and scope

Primary reference: NOV — How to Treat Your Type P Triplex Mud Pump, 25-101131, ©2025, page 14. Accessed 20 September 2026. The model distinction above is a short summary of the OEM publication. The record fields, enquiry structure and handover workflow are our editorial recommendations. Confirm the manual's applicability with the equipment owner or NOV where serial-number coverage or modifications are uncertain.

FAQ

Can the same worksheet cover both listed models?

The administrative fields can be shared, but the installed spray arrangement and inspection location must be entered separately. Do not copy a completed result from one pump to another.

Does a visible spray prove the liner is serviceable?

No. This record documents an observation of the cooling arrangement. It does not replace a separate liner condition assessment or equipment acceptance procedure.

What should be recorded when the outlet cannot be seen safely?

Enter “not observable,” explain the access limitation and assign follow-up under an approved procedure. Do not remove guards or reach into moving machinery to complete the form.

Is a component compatible because it is listed for a Type P pump?

A family name alone is insufficient. Match the installed assembly and applicable drawing, then obtain documented confirmation for the proposed part.